Place of Origin:
Singapore
Certification:
IS9001
Model Number:
3051CD
3051CD Pressure Transmitter Price
Rosemount 3051CD Pressure Transmitter The Rosemount 3051CD is a precision differential pressure transmitter engineered for versatile measurement in flow, level, and pressure applications. Its compact Coplanar™ design ensures seamless integration, while advanced diagnostics, high accuracy, and long-term stability make it a trusted choice for demanding industrial environments.
Feature | 3051CD Standard | 3051CD with Remote Seals | 3051CD High-Pressure Variant |
---|---|---|---|
Measurement Type | Differential Pressure | Differential Pressure with Remote Seals | Differential Pressure (High Static Pressure) |
Sensor Technology | Capacitive | Capacitive | Capacitive |
Pressure Range | Up to 2000 psi (137.89 bar) | Varies by seal configuration | Up to 3626 psi (250 bar) |
Accuracy | ±0.04% of span | ±0.04% of span | ±0.04% of span |
Stability | 10-year stability | 10-year stability | 10-year stability |
Output Signal | 4–20 mA HART®, FOUNDATION™ Fieldbus, Wireless | Same as standard | Same as standard |
Mounting Style | Coplanar™ platform | Coplanar™ with 1199 remote seals | Coplanar™ |
Material Options | 316L SST, Hastelloy®, Tantalum | 316L SST, Alloy C-276, others via seals | 316L SST, Alloy 400 |
Applications | Steam, gas, liquid flow & level | Corrosive or high-temp media | High-pressure steam, gas pipelines |
Certifications | SIL 2/3, Explosion-proof, Intrinsically Safe | Same as standard | Same as standard |
1. Exceptional Accuracy Delivers high-precision measurement with up to ±0.025% of span accuracy, ensuring reliable performance in critical applications.
2. Long-Term Stability Offers ±0.1% URL stability for 10 years, minimizing drift and reducing the need for frequent recalibration.
3. Coplanar™ Platform Patented compact design allows direct manifold and primary element mounting, enhancing installation efficiency and reducing leak paths.
4. Wide Rangeability Supports a 150:1 turndown ratio, enabling a single device to cover a wide range of process conditions.
5. Advanced Diagnostics includes features like Loop Integrity and Plugged Impulse Line Detection to proactively identify potential issues.
6. Multiple Communication Options Integrates with systems via 4–20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus, and PROFIBUS® PA.
7. Bluetooth® Connectivity allows secure, wireless configuration and troubleshooting without opening the transmitter housing—especially useful in hazardous areas.
8. Rugged Construction Materials Offered in 316L SST, Hastelloy®, Alloy C-276, and Tantalum to withstand corrosive and high-temperature environments.
9. Functional Safety Certified SIL 2/3 compliant per IEC 61508, making it suitable for use in Safety Instrumented Systems (SIS).
10. Flexible Mounting & Output Configurations Compatible with various manifolds, seals, and process connections, allowing seamless integration into different systems.
1. Steam Flow Measurement Used with primary elements like orifice plates or Annubar™ sensors to measure steam flow in power plants, HVAC systems, and industrial boilers.
2. Boiler Drum Level Monitoring provides accurate differential pressure readings to determine water level in steam drums, ensuring safe and efficient boiler operation.
3. Liquid Level Measurement in Pressurized Tanks Ideal for closed-tank level applications using differential pressure to calculate liquid height, especially in chemical and food processing.
4. Filter and Pump Monitoring Detects pressure drops across filters or pumps, helping identify clogging or performance degradation in water treatment and process systems.
5. Energy Management Systems are integrated into building automation or industrial energy systems to monitor steam and fluid flow for efficiency optimization.
6. Gas Flow Measurement Measures differential pressure across flow elements in natural gas pipelines or combustion systems for accurate flow control.
7. Safety Instrumented Systems (SIS) SIL 2/3 certification makes it suitable for critical safety loops in oil & gas, refining, and chemical processing.
8. Corrosive or High-Temperature Media. With remote seals and exotic materials, it’s used in harsh environments like acid processing or high-temp steam lines.
1. What is the Rosemount 3051CD used for?
It’s designed for differential pressure measurement in applications like steam flow, liquid level in pressurized tanks, and energy monitoring systems.
2. What communication protocols does it support?
The 3051CD supports 4–20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus, and PROFIBUS® PA, offering flexible integration with control systems.
3. Can the 3051CD be used in safety applications?
Yes, it is SIL 2/3 certified per IEC 61508, making it suitable for use in Safety Instrumented Systems (SIS).
4. What is the accuracy and stability of the transmitter?
It offers up to ±0.025% of span accuracy and ±0.1% URL stability over 10 years, minimizing recalibration needs.
5. Is Bluetooth® configuration available?
Yes, select models include Bluetooth® connectivity for secure, wireless setup and diagnostics—ideal for hazardous or hard-to-reach locations.
6. What materials are available for wetted parts?
Options include 316L SST, Hastelloy®, Alloy C-276, and Tantalum, suitable for corrosive or high-temperature media.
7. Can I use remote diaphragm seals with the 3051CD?
Absolutely. The 3051CD is compatible with 1199 remote seal systems, enabling use in extreme process conditions.
8. How do I trim or calibrate the transmitter?
Trimming can be done using a HART communicator or compatible software. Always follow Emerson’s calibration procedures to maintain performance.
9. What’s the maximum pressure range?
Depending on the configuration, it can handle up to 3626 psi (250 bar) in high-pressure variants.
10. Are spare parts interchangeable across 3051 models?
Only use Emerson-approved parts to maintain pressure integrity and safety compliance.
Send your inquiry directly to us