logo
News
Home > news > Company news about Choosing Between Emerson 3051 Models: DP, GP, and Absolute Pressure
Events
Contact Us
Contact Now

Choosing Between Emerson 3051 Models: DP, GP, and Absolute Pressure

2025-11-13

Latest company news about Choosing Between Emerson 3051 Models: DP, GP, and Absolute Pressure

Choosing Between Emerson 3051 Models: DP, GP, and Absolute Pressure

When it comes to industrial instrumentation, the Emerson Rosemount 3051 Pressure Transmitter is a trusted workhorse. Its versatility allows engineers to deploy one platform across multiple applications, but the key lies in selecting the right measurement type: DP, GP, or Absolute Pressure. Let’s break down the differences and practical use cases.


1. Differential Pressure (DP)

  • Definition: Measures the difference between two pressure points.
  • Typical Applications:
  • Flow measurement using orifice plates, venturi tubes, or pitot tubes.
  • Level measurement in pressurized tanks.
  • Monitoring filter or pump performance.
  • Range: Up to 2000 psi (137.9 bar) differential emerson.cn.
  • Why Choose DP: Ideal when you need to understand how two pressures interact, especially in flow and level calculations.

2. Gauge Pressure (GP)

  • Definition: Measures pressure relative to atmospheric pressure (0 psig = ambient atmosphere).
  • Typical Applications:
  • Monitoring pipeline pressure.
  • Ensuring safe operating conditions in compressors and pumps.
  • General process monitoring where an atmospheric reference is sufficient.
  • Range: Up to 2000 psig (137.9 bar) emerson.cn.
  • Why Choose GP: Best for everyday process monitoring where atmospheric conditions are the baseline.

3. Absolute Pressure (AP)

  • Definition: Measures pressure relative to a perfect vacuum (0 psia = absolute zero).
  • Typical Applications:
  • Vacuum distillation processes.
  • Reactor monitoring in chemical plants.
  • Applications where atmospheric pressure fluctuations would distort readings.
  • Range: Up to 4000 psia (275.8 bar) emerson.cn.
  • Why Choose AP: Critical for high-accuracy applications where atmospheric changes cannot be ignored.

Comparison Table

Model Type Reference Point Typical Range Common Applications
DP Two process points Up to 2000 psi differential Flow, level, filter monitoring
GP Atmospheric pressure Up to 2000 psig Pipelines, compressors, pumps
AP Perfect vacuum Up to 4000 psia Vacuum distillation, reactors

Key Takeaway

  • Choose DP if you need to measure differences (flow, level).
  • Choose GP if you’re monitoring process pressure relative to the atmosphere.
  • Choose AP if accuracy is critical in vacuum or sensitive chemical processes.

Send your inquiry directly to us

Privacy Policy China Good Quality 3051 Transmitter Supplier. Copyright © 2025 Shaanxi Huibo Electromechanical Technology Co., Ltd . All Rights Reserved.